Your browser is no longer supported. Please upgrade your browser to improve your experience.

C•Xchange™ features an extended range of 0 to 90 mS/cm. During long term, in situ deployments, conductivity stability is +/- 0.003 mS/cm/month when used with UV•Xchange™.

Right angle and in-line flow sensors are available. Learn about the benefits offered by the unique 4-electrode design of AML’s conductvity sensor here.

See CT•Xchange™ for conductivity and temperature in one sensor. This combined sensor offers several benefits, including the smaller footprint that allows room for one more sensor than traditionally possible on each X•Series instrument.

Contact

Technical Specification


  • Parameter Conductivity
  • Depth Rating 6000 m
  • Range 0-2 mS/cm 0-90 mS/cm ᵃ ᵇ
  • Response Time 25 ms ʰ
  • Accuracy (+/-) 0.01 mS/cm
  • Precision (+/-) 0.003 mS/cm
  • Stability 0.003 mS/cm/month ͤ
  • Wiper N/A
  • Length 108 mm (4.25″)
  • Diameter 61 mm (2.4″)
  • Resolution 0.001 mS/cm

Data Sheet


ᵃ Standard range
ᵇ Will over-range to 100 mS/cm. Inquire for specifications.
ᶜ Will over-range to 60 ⁰C. Inquire for specifications.
ᵈ Digital auto-ranging
ᵉ When deployed with UV•Xchange™
ᶠ For standard range only. 0.02 m/s for other ranges.
ᵍ For standard range only. 0.5-1.0 m/s for other ranges.
ʰ At 1 m/s flow